Electronic control systems



Electronic control systems are used to automate management processes of various equipment. They are also used for data integration of controlled systems state to combine them into the centers for data collection, data processing and data display.

CP-10, CP-12 - is a panel computer designed for using in automated control systems both as a standalone device that provides algorithms implementation for different purposes, an  information display and as an element of human-machine interaction. The CP is highly resistant to external influences (ambient temperature, dust, moisture, mechanical shock and vibration) and allows you to solve a variety of problems. The configuration changes under the Customer's needs are possible.

The CP is highly resistant to external influences (ambient temperature, dust, moisture, mechanical shock and vibration) and allows you to solve a variety of problems. The configuration changes under the Customer's needs are possible.

ParameterParameter CP-10 CP-12
Screen diagonal, cm (inch) 25 (10) 31 (12)
Monitor resolution 1024×768
Processor type ARM Cortex (A9, 2 cores)
Random Access Memory (RAM) 1 Gb
Micro SD storage capacity 16 Gb

Interfaces and ports, pcs.:

RS-232 (COM)

Ethernet (LAN)

USB

microphone input (MIC)

audio line out (L-OUT)

CNS user interface

 

2

2

2

1

1

1
Supply voltage, V from 10 to 32, constant
The operating range of ambient temperatures, °С from - 40 to + 60
 

PSSC - Power Supply Switching Card is used for remote control and monitoring of connected devices’ power supply. It is designed for installation in automated power supply cabinets.

It can perform control algorithms, both independently and as a part of unified electronic control system.

Parameter Meaning

Interfaces and ports, pcs:

Ethernet (LAN)

CAN

RS-232 (COM)

RS-485

UART/ RS-232/ RS-485

I2C

 

1

4

1

1

1

1
Supply voltage, V from 8 to 32
Number of quantized inputs, pcs. 20

Number of analog inputs, pcs:

for AC voltage measurement up to 380 V

for current measurement (connection via current transformer)

 

3

5

Number of power outputs:

up to 20 Amps

up to 2 Amps

 

6

24

 